Data / Battery storage · Germany

Germany’s battery fleet, home to grid-scale

All 2,904,902 batteries in operation in the official register, plus the pipeline. Filter by segment, size, brand, region, operator, grid level and more; every view can be shared as a link or downloaded as CSV.

Source
Marktstammdatenregister, BNetzA
Export
17 Nov 2026
Coverage
2,935,851 battery units · 35.4 GWh in operation
Refresh
Weekly, automatic

Open data: Download these tables (Parquet, CSV) on Hugging Face

Key insights · 17 Nov 2026

What the register says

  • Growth · January to November 20269.87 GWh

    of battery capacity was commissioned this year, up 63% on the same months of 2025. Large-scale batteries are 45% of it.

    See this year →
  • Grid-scale boom4.40 GWh

    of large-scale batteries were commissioned in 2026 so far, more than the 4.09 GWh built in all earlier years combined (52% of today’s large-scale fleet).

    Explore large-scale →
  • Pipeline38.1 GWh

    of large-scale projects are registered as in planning, 4.5× today’s operating large-scale fleet. Sachsen and Brandenburg hold 53% of it, and one operator, LEAG Clean Power GmbH, 48%.

    Open the pipeline →
  • Plug-in batteries37%

    of new residential battery systems in 2026 are plug-in (balcony) batteries, against 12% in 2024. At 3.4 kWh on average, they are only 15% of new residential capacity.

    See plug-in batteries →
  • Home battery size11.2 kWh

    is the average new home battery in 2026 (plug-in excluded), against 8.2 kWh in 2018. Homes with PV now install 1.04 kWh of battery per kWp of solar.

    Explore home batteries →
  • Longer batteries2.2 h

    is the average duration of large-scale batteries commissioned in 2026, against 1.1 h in 2020–2022. Longer batteries move more midday solar into the evening and earn more from price spreads.

    See durations →
  • Who owns home batteries98.5%

    of new residential batteries in 2026 are registered to private households. Leasing and rental companies barely show up as operators: the largest, e-regio GmbH & Co. KG, runs 594 home batteries in total.

    See organisations →
  • Ready for a virtual power plant?89%

    of large-scale capacity in operation is registered as remotely controllable by a direct marketer, against 0.0% of residential capacity. Home batteries are a large, mostly untapped flexibility pool.

    Filter by remote control →
  • Read recent months with care54 days

    pass before 90% of home batteries are registered (median 5 days); for large-scale it is 97 days. The latest two months always look weaker than they will end up.

    See this year →

Explorer

Slice the fleet

Loading the fleet data…

Method

How these numbers are built

  1. Pull

    Every Monday a scheduled job reads the needed files of the MaStR full export from the BNetzA server: storage units and plants, EEG records, solar units, locations, grid connection points and market actors.

  2. Join

    Each battery unit gets its plant’s usable capacity (split evenly when a plant has several units), its paired solar (registered together, or the same operator’s solar at the same postcode), its grid connection (voltage, grid operator), whether other generators share its site, and its operator type.

  3. Clean

    Batteries only, in operation or in planning. Left out: 180 with more than 24 h per kW (likely Wh typed as kWh); 59 with no usable capacity.

  4. Classify

    Segments by usable capacity: residential < 30 kWh, commercial & industrial 30 kWh to 1 MWh, large-scale ≥ 1 MWh (as in RWTH’s Battery Charts). Plug-in: paired with a plug-in solar unit, named as balcony or plug-in, a plug-in brand, or ≤ 0.8 kW and ≤ 8 kWh. C&I sector: usage sector of the paired solar, else the operator’s registered industry.

  5. Brands

    The register has no brand field. 7.6% of units name a brand in free text. For the others, each exact (power, capacity, coupling) signature is split across brands in the same proportions as the named units with that signature. Tested on held-out named units, the estimated brand shares match the true shares within about two points.

Data: Bundesnetzagentur, Marktstammdatenregister, export of 17 Nov 2026, licensed under Datenlizenz Deutschland – Namensnennung – 2.0. Recent months are incomplete because of late registrations. Planned units are only those registered early. Scripts: scripts/data/. Built 2026-11-18.

Glossary

What the labels mean

Systems
Registered battery units. One unit is one battery system as registered in the Marktstammdatenregister.
Usable capacity
Usable storage capacity: the energy the battery can actually deliver, as registered by the operator.
Power
Net rated power (Nettonennleistung): the maximum continuous output of the unit. Some publications use gross power, which reads about 4% higher for home batteries.
Duration (hours)
Capacity ÷ power: how many hours the battery can run at full power. Grid batteries are usually 1 to 4 hours.
kWh per kWp
Battery capacity per kW of paired PV, capacity-weighted, over batteries with PV. Around 1 kWh per kWp is the usual rule of thumb for homes.
In planning
Units registered with the status “in planning”. Registration before commissioning is optional, so the real pipeline is larger; not every project will be built.
Bundesland
Federal state where the battery is installed.
Brand
Manufacturer named in the register, or estimated from the battery’s power and capacity signature. Some names are the inverter brand.
Brand basis
Named: the brand appears in the unit name in the register. Estimated: split across brands in the same proportions as named units with the identical power, capacity and coupling. Unidentified: no match.
PV pairing
Whether a solar system belongs to the battery: registered together with it, or owned by the same operator at the same postcode.
Coupling
AC-coupled batteries have their own inverter and connect on the AC side; DC-coupled batteries share the PV hybrid inverter.
Feed-in mode
Self-consumption first: the site uses its own power and exports the surplus. Full feed-in: all output goes to the grid.
Remote control
Whether the grid operator and/or a direct marketer (for example a virtual power plant) can control the unit remotely, as registered.
Operator type
Who runs the battery. Organisations include companies, utilities, municipalities and leasing or rental providers. Private persons stay anonymous in the register.
Voltage level
Grid level of the connection point. Low voltage is the household connection; large batteries connect at medium, high or extra-high voltage.
Site
Co-located: other generation units (for example solar or wind) are registered at the same location. Standalone: only storage at the location.
Tender award
The unit won a federal tender (mostly innovation tenders, which pair storage with solar or wind).
Chemistry
Battery technology as registered.
TSO control area
The transmission system operator’s control area: 50Hertz (east), Amprion (west), TenneT (north and Bavaria), TransnetBW (Baden-Württemberg).